Skip to main content

Table 2 Particle to protein ratio coefficients of variation for each method and biological replicate

From: Establishment of minimum protein standards for Mycobacterium tuberculosis-derived extracellular vesicles through comparison of EV enrichment methods

Method

Biological Replicate

Technical Replicate Average Particles per µg

Technical Replicate Standard Deviation

Technical Replicate CoV (%)

Average Technical Replicate CoV (%)

Method Average Particles per µg

Method Standard Deviation

Method CoV (%)

CC

1

4.03E + 08

6.33E + 07

15.7

11.55

4.97E + 08

1.19E + 08

24.0

CC

2

6.40E + 08

5.15E + 07

8.0

CC

3

4.48E + 08

4.88E + 07

10.9

qEV

1

1.98E + 09

1.62E + 08

8.2

15.39

2.45E + 09

6.32E + 08

25.8

qEV

2

3.12E + 09

2.47E + 08

7.9

qEV

3

2.25E + 09

6.77E + 08

30.1

UC

1

5.62E + 08

4.86E + 07

8.7

28.18

1.07E + 09

5.65E + 08

52.9

UC

2

1.53E + 09

6.56E + 08

42.9

UC

3

1.11E + 09

3.68E + 08

33.0

DG

1

6.21E + 08

1.06E + 08

17.1

13.94

4.43E + 09

3.07E + 09

69.1

DG

2

5.31E + 09

4.32E + 08

8.1

DG

3

7.37E + 09

1.22E + 09

16.6